High efficient real-time PCR Master Mix
Code No. QPS-101T 40 reactions, QPS-101 200 reactions/Code No. QPS-201T 40 reactions, QPS-201 200 reactions
THUNDERBIRD™ Probe and SYBR® qPCR Mix is a highly efficient 2x Master Mix for real-time PCR using TaqMan™ probes and SYBR® Green I. The master mix contains all required components, except for ROX reference dye, probe and primers (50x ROX reference dye is individually supplied with this kit). The master mix facilitates reaction setup, and improves the reproducibility of experiments.
These products are improved versions of Realtime PCR Master Mix (Code No. QPK-101) and Realtime PCR Master Mix (Code No. QPK-201) . In particular, reaction specificity and PCR efficiency is enhanced.
This product is sold in U.S. under the license of US patent 7772383
from Chakrabarti Advanced Technology NewCo LLC.
Store at -20ºC
THUNDERBIRD™ Probe qPCR Mix | 1 mL × 1 |
50x ROX reference dye | 50 µL × 1 |
THUNDERBIRD™ Probe qPCR Mix | 1.67 mL × 3 |
50x ROX reference dye | 250 µL × 1 |
THUNDERBIRD™ SYBR® qPCR Mix | 1 mL × 1 |
50x ROX reference dye | 50 µL × 1 |
THUNDERBIRD™ SYBR® qPCR Mix | 1.67 mL × 3 |
50x ROX reference dye | 250 µL × 1 |
Applied Biosystems |
ABI PRISM™ 7000 | Roche Diagnostics |
LightCycler™ 1.x / 2.0 |
---|---|---|---|
ABI PRISM™ 7700 | LightCycler™ Nano | ||
Applied Biosystems™ 7300 | LightCycler™ 480 | ||
Applied Biosystems™ 7500/7500FAST | Bio-Rad / MJ | MiniOpticon™ | |
Applied Biosystems™ 7900HT | CFX96 Touch™ | ||
Applied Biosystems™ StepOne™ | Agilent Technologies |
Mx3000P / Mx3005P / Mx4000 | |
Applied Biosystems™ StepOnePlus™ | TaKaRa | Thermal Cycler Dice™ Real Time Systems |
β-actin mRNA was detected with serially diluted cDNA from HeLa cell total RNA. THUNDERBIRD™ SYBR® qPCR Mix [Code No. QPS-201] showed greater sensitivity and efficiency than other kits (companies A and B).
Norovirus G1 and human GAPDH genes were detected using serially diluted cDNA samples by SYBR® Green I and TaqMan real-time PCR. THUNDERBIRD™ qPCR Master Mix showed greater efficiency than other reagents.
Detection of Norovirus G1 gene
by SYBR® Green I assay.
[Roche Diagnostics LightCycler 1.1]
Detection of GAPDH gene
by TaqMan™ assay.
[Roche Diagnostics LightCycler 1.1]
Human GAPDH genes were detected using serially 20.5 fold diluted cDNA synthesised from HeLa cell total RNA by SYBR® Green I assay. THUNDERBIRD™ qPCR Master Mix successfully detected the differences between dilutions.
Detection of human GAPDH gene by SYBR® GREEN I assay.
[Applied Biosystems 7900HT]